Nutanix Metro Availability (MA):
Lets see requirements for implementing this feature:
NOS Version:
NOS 4.1 or later
Networking:
1.
<=5ms RTT latency
2.
<400 between="" both="" distance="" kms="" o:p="" sites="">400>
3.
Bandwidth depends on “data change rate”
4.
Redundant
physical network connection
Hardware:
1.
2 Nutanix clusters at each site
2.
mix/match models (eg: NX3000 at primary site and
NX6000 at DR Site)
Hypervisor:
1.
ESXi 5.x supported
2.
KVM/Hyper-V not now, maybe later
Nutanix License:
1.
Ultimate
MA supports compression-over-the-wire which reduces
bandwidth utilization significantly during replication.
Though it is only few clicks to configure the Metro
Availability feature, but it requires few other configurations. Technically,
the container is getting replicated to the DR site. So, the container name must
be same for both sites (reason behind this the same datastore name maintained
in VM configuration file to avoid re-registering the VMs in the DR site).
Step 1:
Create the Container on the both sites using the same
name. Select the “Storage” from Prism
UI, click the Container option. The Data
de-duplication and compression supported on the containers for MA.
Step 2:
Create the Remote Site, Select the “Data Protection” from
the Prism UI, and then click “Remote Site”
Enter the name for Remote site and enter IP Address of CVMs
of the target site.
Select the Use SSH Tunnel if you are planning to use the SSH
tunnel between both sites. Select the
“Disaster Recovery” without fail. VStore
name mapping not required.
Repeat the same setup on the DR site, but enter IP address
of Primary site CVMs. After the configuration, test the connection between both
sites using Test Connection option
Step 3:
Time to configure the Metro Availability (MA), select the
Data Protection from Prism UI, click the “Protection Domain” and select “Metro
Availability”
Enter name for MA, press Next.
Select the container to replication, you cannot select multiple containers.
Then select the remote site from compatible Remote site
(Upper window)
In
the VM Availability screen, select the method to disable the MA either manually
or automatically after specified time when a network or any other problem
interrupts the connection between both sites.
Press
Next, in the “Review” screen verify the all the configuration and click the
“Create” button.
Step
4:
Activate
the Metro Availability , click the “Metro Availability” in the “Protection
Domain”, select the target container, Click the “Activate” button. Make sure
that target container is empty, else MA will delete the data from the
container.